Red color represents old content. It may be empty showing addition in the new version.
Green color represents new content. It may be empty showing deletion in the new version.
Inline
Side by side
Added new contents,
deleted old contents,contents that are not changed.
New table contents
New table contents
Old table contents
Old table contents
Unchanged contents
Unchanged contents
Added new contents, contents that are not changed.
Deleted old contents, contents that are not changed.
Old table contents
Old table contents
Unchanged contents
Unchanged contents
New table contents
New table contents
Unchanged contents
Unchanged contents
اطلاعات عمومی
ندارد
دارد
nusedused
3
2
32
خالی
This update is being made to clarify and complete the registered information regarding the conduct of the study and to improve the consistency of the trial record with the study protocol and the actual procedures used during the study. These updates do not change the overall nature of the intervention or the main objectives of the study.
This update is being made to clarify and complete the registered information regarding the conduct of the study and to improve the consistency of the trial record with the study protocol and the actual procedures used during the study. These updates do not change the overall nature of the intervention or the main objectives of the study.
خالی
این بهروزرسانی با هدف شفافسازی و تکمیل اطلاعات ثبتشده در خصوص نحوه اجرای مطالعه و افزایش تطابق رکورد کارآزمایی با پروتکل مطالعه و روش اجرای واقعی آن انجام شده است.. این بهروزرسانی با هدف افزایش شفافیت، قابلیت بازتولید و تطابق اطلاعات ثبتشده با مطالعه انجام شده است و ماهیت کلی مداخله و اهداف اصلی مطالعه را تغییر نمیدهد.
این بهروزرسانی با هدف شفافسازی و تکمیل اطلاعات ثبتشده در خصوص نحوه اجرای مطالعه و افزایش تطابق رکورد کارآزمایی با پروتکل مطالعه و روش اجرای واقعی آن انجام شده است.. این بهروزرسانی با هدف افزایش شفافیت، قابلیت بازتولید و تطابق اطلاعات ثبتشده با مطالعه انجام شده است و ماهیت کلی مداخله و اهداف اصلی مطالعه را تغییر نمیدهد.
In control group 1; headphones are placed on the patient's ear. But the headphones have no function, and the patient is able to hear the surrounding sounds naturally through the holes made on the ear part of the headphones. In control group 2; healthy headphones but without sound function are placed on the patient's ear so that he cannot hear the surrounding sounds. In intervention groups; healthy headphones with a specific frequency are used. Due to the appearance of identical interventions and the patient's lack of information about the grouping and type of stimulation intervention frequency, the patients were blinded to the intervention. Anesthesia and administration of patients during anesthesia is done by the project colleague. Audio frequency was applied through headphones and audio frequency settings were done through Bluetooth headphones. The other colleague who registers the variables does not know the way of grouping and the type of frequency received by the patients.
In Control Group 1, headphones were placed over the patient’s ears; however, the headphones had no audio function and contained openings over the ear area, allowing patients to hear environmental sounds naturally. In Control Group 2, intact but inactive headphones were placed over the patient’s ears, preventing the patients from hearing environmental sounds. In the intervention groups, intact headphones were used to deliver auditory stimulation at the specified frequencies. Because the headphones were visually identical and patients were unaware of their group allocation and the frequency of the auditory stimulation, patients were blinded to both group assignment and intervention frequency. An investigator involved in the project was responsible for administering anesthesia and managing the patients throughout the anesthetic period and was blinded to group allocation and stimulation frequency. Auditory stimulation was delivered through the headphones, with the stimulation frequency configured via the headphones’ Bluetooth connection. Another researcher responsible for recording the study variables was unaware of the patients’ group allocation and the frequency of auditory stimulation received and was blinded to both. Statistical analyses were performed after completion of data collection.
In control groupControl Group 1;, headphones arewere placed onover the patient's ear. Butpatient’s ears; however, the headphones havehad no audio function, and contained openings over the patient is ableear area, allowing patients to hear the surroundingenvironmental sounds naturally through the holes made on the ear part of the headphones. In control groupControl Group 2; healthy, intact but inactive headphones but without sound function arewere placed onover the patient's ear so that he cannot hearpatient’s ears, preventing the surroundingpatients from hearing environmental sounds. In the intervention groups; healthy, intact headphones with a specific frequency arewere used. Due to deliver auditory stimulation at the appearancespecified frequencies. Because the headphones were visually identical and patients were unaware of identical interventionstheir group allocation and the patient's lackfrequency of information about the grouping and type ofauditory stimulation intervention frequency, the patients were blinded to the intervention. Anesthesiaboth group assignment and administration of patients during anesthesia is done byintervention frequency. An investigator involved in the project colleaguewas responsible for administering anesthesia and managing the patients throughout the anesthetic period and was blinded to group allocation and stimulation frequency. AudioAuditory stimulation was delivered through the headphones, with the stimulation frequency was applied throughconfigured via the headphones and audio frequency settings were done through’ Bluetooth headphonesconnection. The other colleague who registersAnother researcher responsible for recording the study variables does not knowwas unaware of the way of groupingpatients’ group allocation and the typefrequency of frequencyauditory stimulation received by the patientsand was blinded to both. Statistical analyses were performed after completion of data collection.
در گروه کنترل 1؛ هدفون بر روی گوش بیمار قرار داده می شود. ولی هدفون فاقد عملکرد می باشد و همچنین از طریق سوراخ های که بر روی قسمت روی گوش هدفون انجام شده است بیمار قادر به شنیدن صداهای محیطی بصورت طبیعی است. در گروه کنترل 2؛ هدفون سالم ولی فاقد عملکرد صوتی بر روی گوش بیمار قرار داده می شود بطوری که قادر به شنیدن صداهای محیطی نباشد. در گروه های مداخله؛ هدفون سالم با فرکانس مشخص استفاده می شود. با توجه به مداخلات ظاهری یکسان و عدم اطلاع بیمار از گروه بندی و نوع فرکانس مداخله تحریکی بیماران نسبت به مداخله کور بودند. انجام بیهوشی و اداره بیماران در طول بیهوشی توسط همکار پروژه انجام می شود. اعمال فرکانس صوتی از طریق هدفون و تنظیمات فرکانس صوتی از طریق بلوتوث هدفون انجام می شد. همکار دیگر ثبت کننده متغییر ها از نحوه گروه بندی و نوع فرکانس دریافتی بیماران اطلاعی ندارد.
در گروه کنترل 1، هدفون روی گوش بیمار قرار داده میشد، اما هدفون فاقد عملکرد صوتی بود و بهدلیل وجود سوراخهایی در قسمت روی گوش هدفون، بیمار قادر بود صداهای محیطی را بهطور طبیعی بشنود. در گروه کنترل 2، هدفون سالم اما فاقد عملکرد صوتی روی گوش بیمار قرار داده میشد، بهگونهای که بیمار قادر به شنیدن صداهای محیطی نبود. در گروههای مداخله، از هدفون سالم برای ارائه تحریک صوتی با فرکانس مشخص استفاده میشد. با توجه به ظاهر مشابه هدفونها و عدم اطلاع بیماران از تخصیص گروهی و نوع فرکانس تحریک، بیماران نسبت به گروه و نوع مداخله کور بودند. انجام بیهوشی و اداره بیماران در طول دوره بیهوشی توسط همکار پروژه انجام میشد و متخصص بیهوشی نسبت به تخصیص گروهی و نوع فرکانس تحریک کور بود. اعمال تحریک صوتی از طریق هدفون و تنظیم فرکانس صوتی از طریق اتصال بلوتوث هدفون انجام میشد. پژوهشگر دیگری که مسئول ثبت متغیرهای مطالعه بود، از تخصیص گروهی و نوع فرکانس صوتی دریافتی بیماران اطلاعی نداشت و نسبت به این موارد کور بود. دادهها پس از تکمیل جمعآوری دادهها مورد تحلیل آماری قرار گرفتند.
در گروه کنترل 1؛، هدفون بر روی گوش بیمار قرار داده می شود. ولیشد، اما هدفون فاقد عملکرد می باشدصوتی بود و همچنین از طریقبهدلیل وجود سوراخ های که بر رویهایی در قسمت روی گوش هدفون انجام شده است، بیمار قادر بود صداهای محیطی را بهطور طبیعی بشنود. در گروه کنترل 2، هدفون سالم اما فاقد عملکرد صوتی روی گوش بیمار قرار داده میشد، بهگونهای که بیمار قادر به شنیدن صداهای محیطی بصورت طبیعی استنبود. در گروه کنترل 2؛های مداخله، از هدفون سالم ولی فاقد عملکردبرای ارائه تحریک صوتی بر روی گوش بیمار قرار داده می شود بطوری که قادر به شنیدن صداهای محیطی نباشد. در گروه های مداخله؛ هدفون سالم با فرکانس مشخص استفاده می شودشد. با توجه به مداخلات ظاهری یکسانظاهر مشابه هدفونها و عدم اطلاع بیماربیماران از گروه بندیتخصیص گروهی و نوع فرکانس مداخله تحریکیتحریک، بیماران نسبت به گروه و نوع مداخله کور بودند. انجام بیهوشی و اداره بیماران در طول دوره بیهوشی توسط همکار پروژه انجام می شودشد و متخصص بیهوشی نسبت به تخصیص گروهی و نوع فرکانس تحریک کور بود. اعمال فرکانستحریک صوتی از طریق هدفون و تنظیماتتنظیم فرکانس صوتی از طریق اتصال بلوتوث هدفون انجام میشد. همکار دیگرپژوهشگر دیگری که مسئول ثبت کننده متغییر هامتغیرهای مطالعه بود، از نحوه گروه بندیتخصیص گروهی و نوع فرکانس صوتی دریافتی بیماران اطلاعی نداردنداشت و نسبت به این موارد کور بود. دادهها پس از تکمیل جمعآوری دادهها مورد تحلیل آماری قرار گرفتند.
متغیر پیامد اولیه
#1
Heart rate is measured before, immediately and also in 1, 3 and 5 minutes after intubation and extubation.
It is measured immediately and at 1, 2, 3, 4, and 5 minutes after intubation and extubation.
Heart rateIt is measured before, immediately and also inat 1, 2, 3, 4, and 5 minutes after intubation and extubation.
ضربان قلب قبل، بلافاصله و همچنین در دقایق 1، 3 و 5 بعد از لوله گذاری و خارج کردن لوله اندازه گیری می شود.
بلافاصله و همچنین در دقایق 1، 2، 3، 4 و 5 بعد از لوله گذاری و خارج کردن لوله اندازه گیری می شود.
ضربان قلب قبل، بلافاصله و همچنین در دقایق 1، 2، 3، 4 و 5 بعد از لوله گذاری و خارج کردن لوله اندازه گیری می شود.
#2
Systolic and diastolic blood pressure
mean arterial pressure
Systolic and diastolic bloodmean arterial pressure
فشار خون سیستولیک و دیاستولیک
فشار خون میانگین
فشار خون سیستولیک و دیاستولیکمیانگین
Systolic and diastolic Blood pressure is measured before, immediately and also in 1, 3 and 5 minutes after intubation and extubation.
It is measured immediately and at 1, 2, 3, 4, and 5 minutes after intubation and extubation.
Systolic and diastolic Blood pressureIt is measured before, immediately and also inat 1, 2, 3, 4, and 5 minutes after intubation and extubation.
فشار خون سیستولیک و دیاستولیک قبل، بلافاصله و همچنین در دقایق 1، 3 و 5 بعد از لوله گذاری و خارج کردن لوله اندازه گیری می شود.
بلافاصله و همچنین در دقایق 1، 2، 3، 4 و 5 بعد از لوله گذاری و خارج کردن لوله اندازه گیری می شود.
فشار خون سیستولیک و دیاستولیک قبل، بلافاصله و همچنین در دقایق 1، 2، 3، 4 و 5 بعد از لوله گذاری و خارج کردن لوله اندازه گیری می شود.
Systolic and diastolic blood pressure
using a monitor connected to the patient.
Systolic and diastolic blood pressureusing a monitor connected to the patient.
#3
Before leaving the recovery department
Before discharge from the recovery unit and at 1, 3, and 6 hours after surgery.
Before leavingdischarge from the recovery departmentunit and at 1, 3, and 6 hours after surgery.
قبل از خروج از بخش ریکاوری
قبل از خروج از بخش ریکاوری و در ساعات 1، 3و 6 بعد از جراحی
قبل از خروج از بخش ریکاوری و در ساعات 1، 3و 6 بعد از جراحی
#4
Using patient-connected monitoring
using a monitor connected to the patient
Usingusing a monitor connected to the patient-connected monitoring
#5
خالی
Bispectral Index value during general anesthesia
Bispectral Index value during general anesthesia
خالی
مقدار شاخص دوطیفی در طی بیهوشی عمومی
مقدار شاخص دوطیفی در طی بیهوشی عمومی
خالی
Before induction of general anesthesia, after induction of general anesthesia, and at 15, 30, 45, and 60 minutes, as well as after extubation.
Before induction of general anesthesia, after induction of general anesthesia, and at 15, 30, 45, and 60 minutes, as well as after extubation.
خالی
قبل از القای بیهوشی عمومی، پس از القای بیهوشی عمومی، و در دقایق ۱۵، ۳۰، ۴۵، ۶۰ و بعد از اکستوباسیون
قبل از القای بیهوشی عمومی، پس از القای بیهوشی عمومی، و در دقایق ۱۵، ۳۰، ۴۵، ۶۰ و بعد از اکستوباسیون
خالی
Continuous monitoring using a bispectral index monitor with a disposable forehead sensor
Continuous monitoring using a bispectral index monitor with a disposable forehead sensor
خالی
پایش مداوم با استفاده از دستگاه اندازهگیری شاخص دوطیفی و حسگر یکبارمصرف پیشانی
پایش مداوم با استفاده از دستگاه اندازهگیری شاخص دوطیفی و حسگر یکبارمصرف پیشانی
گروههای مداخله
#1
Control group: patients do not receive any stimulation intervention.
Control 1 group: perforated wireless headphones are placed over both ears, and patients do not receive any auditory stimulus or stimulation intervention. The perforated headphones allow ambient sounds to remain audible.
Control 1 group: perforated wireless headphones are placed over both ears, and patients do not receive any auditory stimulus or stimulation intervention. The perforated headphones allow ambient sounds to remain audible.
گروه کنترل: بیماران هیچ گونه مداخله تحریکی دریافت نمی کنند.
گروه کنترل1: گروه کنترل: هدفون بیسیم سوراخدار روی هر دو گوش قرار داده میشود و بیماران هیچگونه محرک یا مداخله تحریک صوتی دریافت نمیکنند. هدفون سوراخدار امکان شنیدن صدای محیط را فراهم میکند
گروه کنترل1: گروه کنترل: هدفون بیسیم سوراخدار روی هر دو گوش قرار داده میشود و بیماران هیچگونه محرک یا مداخله تحریکیتحریک صوتی دریافت نمیکنند. هدفون سوراخدار امکان شنیدن صدای محیط را فراهم میکند
#2
Control group: passive wireless headphones are placed on each ear so that the intensity of the ambient sound is less than 5 dB, and the patients in this group do not receive any sound stimuli.
Control 2 group: passive wireless headphones are placed over both ears to reduce the intensity of ambient sound to less than 5 dB, and patients in this group do not receive any sound stimuli.
Control 2 group: passive wireless headphones are placed on each ear so thatover both ears to reduce the intensity of the ambient sound isto less than 5 dB, and the patients in this group do not receive any sound stimuli.
گروه کنترل: هدفون بی سیم غیرفعال روی هر دوگوش قرار داده می شود تا شدت دریافت صدای محیط به کمتر از 5 دسی بل برسد و بیماران در این گروه هیچ محرک صوتی دریافت نمی کنند.
گروه کنترل 2: هدفون بیسیم غیرفعال روی هر دو گوش قرار داده میشود تا شدت صدای محیط به کمتر از 5 دسیبل برسد و بیماران در این گروه هیچ محرک صوتی دریافت نمیکنند.
گروه کنترل 2: هدفون بیسیم غیرفعال روی هر دوگوشدو گوش قرار داده میشود تا شدت دریافت صدای محیط به کمتر از 5 دسیبل برسد و بیماران در این گروه هیچ محرک صوتی دریافت نمیکنند.
چکیده پروتکل
هدف ازمطالعه
تعیین اثرات بکارگیری فرکانس های صوتی بر میزان بی دردی و اختلالات همودینامیک در طول لوله¬گذاری و خارج کردن لوله تراشه در بیماران تحت بیهوشی عمومی
طراحی
مطالعه حاضر یک کارآزمایی بالینی تصادفی دوسوکور در فاز ۲ با گروه کنترل است که بر روی ۱۷۵ بیمار انجام می شود. تصادفی سازی نمونه ها با استفاده از ترتیب حروف تصادفی توسط نرمافزار کامپیوتری انجام می شود
نحوه و محل انجام مطالعه
مطالعه بر روی بیماران الکتیو کاندید بیهوشی عمومی در بیمارستان امام رضا شهر کرمانشاه انجام می شود. در گروه های مداخله، اعمال فرکانس های صوتی مختلف طی فرآیند بیهوشی عمومی بوسیله هدفون انجام می شود. بیماران و محقق ثبت کننده اطلاعات از گروه بندی و نوع مداخله اطلاعی ندارند
شرکت کنندگان/شرایط ورود و عدم ورود
بیمارانی که تحت بیهوشی عمومی قرار می گیرند.
گروههای مداخله
در گروه کنترل 1; بیماران هیچ گونه تحریک صوتی دریافت نمی کنند.
در گروه کنترل 2; هدفونهای بیسیم غیرفعال روی هر دو گوش بیمار قرار میگیرند تا شدت صدای محیط کمتر از 5 دسیبل باشد و بیمار هیچ گونه محرک صوتی دریافت نکند.
در گروههای مداخله: تحریک صوتی با فرکانسهای 5، 10، 20، 50 و 100 هرتز از بدو ورود به اتاق عمل تا خروج بیمار از اتاق ریکاوری از طریق هدفونهای بیسیم تحریک صوتی با شدت صدای 50 دسیبل دریافت میکند.
این بهروزرسانی با هدف شفافسازی و تکمیل اطلاعات ثبتشده در خصوص نحوه اجرای مطالعه و افزایش تطابق رکورد کارآزمایی با پروتکل مطالعه و روش اجرای واقعی آن انجام شده است.. این بهروزرسانی با هدف افزایش شفافیت، قابلیت بازتولید و تطابق اطلاعات ثبتشده با مطالعه انجام شده است و ماهیت کلی مداخله و اهداف اصلی مطالعه را تغییر نمیدهد.
نام اختصاری
اطلاعات ثبت در مرکز
شماره ثبت کارآزمایی در مرکز:IRCT20240123060780N3
تاریخ تایید ثبت در مرکز:2024-06-08, ۱۴۰۳/۰۳/۱۹
زمانبندی ثبت:prospective
آخرین بروز رسانی:2026-10-08, ۱۴۰۵/۰۷/۱۶
تعداد بروز رسانیها:1
تاریخ تایید ثبت در مرکز
2024-06-08, ۱۴۰۳/۰۳/۱۹
اطلاعات تماس ثبت کننده
نام
رسول کاویان نژاد
نام سازمان / نهاد
کشور
جمهوری اسلامی ایران
تلفن
+98 83 3427 4618
آدرس ایمیل
r.kavyannejad@kums.ac.ir
وضعیت بیمار گیری
بیمار گیری تمام شده
منبع مالی
تاریخ شروع بیمار گیری مورد انتظار
2024-07-22, ۱۴۰۳/۰۵/۰۱
تاریخ پایان بیمار گیری مورد انتظار
2025-07-23, ۱۴۰۴/۰۵/۰۱
تاریخ شروع بیمارگیری تحقق یافته
خالی
تاریخ پایان بیمارگیری تحقق یافته
خالی
تاریخ خاتمه کارآزمایی
خالی
عنوان علمی کارآزمایی
اثرات بکارگیری فرکانس های صوتی بر میزان بی دردی و اختلالات همودینامیک در طول لوله گذاری و خارج کردن لوله تراشه در بیماران تحت بیهوشی عمومی
عنوان عمومی کارآزمایی
اثرات بکارگیری فرکانس های صوتی بر میزان بی دردی و تغییرات همودینامیک
هدف اصلی مطالعه
درمانی
شرایط عمده ورود و عدم ورود به مطالعه
شرایط عمده ورود به مطالعه قبل از تصادفی سازی:
نداشتن سابقه بیماری های زمینه ای مانند فشار خون، دیابت، بیماری های قلبی و ریوی
بیماران دارای طبقه بندی 1 و 2 انجمن بیهوشی آمریکا (ASA)
گرید ۱ راه هوایی
عدم دریافت پره مدیکاسیون شب قبل و صبح عمل
داشتن حس شنوایی عادی کامل (آستانه شنوایی 25 دسی بل)
داشتن هوشیاری کامل
شرایط عمده عدم ورود به مطالعه قبل از تصادفی سازی:
سابقه مصرف سیگار و اعتیاد
داشتن عفونت گوش و ناهنجاری های آناتومیک سیستم شنوایی
عدم همکاری بیمار
سن
از سن 20 ساله تا سن 50 ساله
جنسیت
هر دو
فاز مطالعه
2
گروههای کور شده در مطالعه
شرکت کننده
مراقب بالینی
ارزیابی کننده پیامد
حجم نمونه کل
حجم نمونه پیشبینی شده:
175
تصادفی سازی (نظر محقق)
اختصاص تصادفی به گروههای مداخله و کنترل
توصیف نحوه تصادفی سازی
تصادفی سازی نمونه ها در این مطالعه توسط نرمافزار کامپیوتری انجام می شود. با توجه به 7 گروه بودن یک ترتیب تصادفی از حروف A, B, C, D, E, F, G در بلاکهایی با تعداد تصادفی 7 حرف ساخته می شود. به ترتیب هر حرف نماد یکی از گروه های مطالعه می باشد. سپس این بلاک های بدست آمده، درون پاکت های دربسته قرار داده می شود. یکی از محققین قبل از شروع مطالعه، یکی از پاکت ها را باز کرده و در نهایت بیمار در یکی از گروه های مداخله یا کنترل قرار می گیرد.
کور سازی (به نظر محقق)
دو سویه کور
توصیف نحوه کور سازی
در گروه کنترل 1، هدفون روی گوش بیمار قرار داده میشد، اما هدفون فاقد عملکرد صوتی بود و بهدلیل وجود سوراخهایی در قسمت روی گوش هدفون، بیمار قادر بود صداهای محیطی را بهطور طبیعی بشنود. در گروه کنترل 2، هدفون سالم اما فاقد عملکرد صوتی روی گوش بیمار قرار داده میشد، بهگونهای که بیمار قادر به شنیدن صداهای محیطی نبود. در گروههای مداخله، از هدفون سالم برای ارائه تحریک صوتی با فرکانس مشخص استفاده میشد. با توجه به ظاهر مشابه هدفونها و عدم اطلاع بیماران از تخصیص گروهی و نوع فرکانس تحریک، بیماران نسبت به گروه و نوع مداخله کور بودند. انجام بیهوشی و اداره بیماران در طول دوره بیهوشی توسط همکار پروژه انجام میشد و متخصص بیهوشی نسبت به تخصیص گروهی و نوع فرکانس تحریک کور بود. اعمال تحریک صوتی از طریق هدفون و تنظیم فرکانس صوتی از طریق اتصال بلوتوث هدفون انجام میشد. پژوهشگر دیگری که مسئول ثبت متغیرهای مطالعه بود، از تخصیص گروهی و نوع فرکانس صوتی دریافتی بیماران اطلاعی نداشت و نسبت به این موارد کور بود. دادهها پس از تکمیل جمعآوری دادهها مورد تحلیل آماری قرار گرفتند.
دارو نما
دارد
اختصاص به گروههای مطالعه
موازی
سایر مشخصات طراحی مطالعه
کد ثبت در سایر مراکز ثبت بینالمللی
خالی
تاییدیه کمیتههای اخلاق
1
کمیته اخلاق
نام کمیته اخلاق
کمیته اخلاق دانشگاه علوم پزشکی کرمانشاه
آدرس خیابان
کرمانشاه، بلوار شهید بهشتی، ساختمان شماره 2 علوم پزشکی، معاونت تحقیقات و فناوری
شهر
كرمانشاه
استان
کرمانشاه
کد پستی
6715847141
تاریخ تایید
2024-01-30, ۱۴۰۲/۱۱/۱۰
کد کمیته اخلاق
IR.KUMS.REC.1403.102
بیماریهای (موضوعات) مورد مطالعه
1
شرح
درد
کد ICD-10
G89.1
توصیف کد ICD-10
Acute pain, not elsewhere classified
2
شرح
درد جراحی
کد ICD-10
G89.18
توصیف کد ICD-10
Other acute postprocedural pain
متغیر پیامد اولیه
1
شرح متغیر پیامد
ضربان قلب
مقاطع زمانی اندازهگیری
بلافاصله و همچنین در دقایق 1، 2، 3، 4 و 5 بعد از لوله گذاری و خارج کردن لوله اندازه گیری می شود.
نحوه اندازهگیری متغیر
با استفاده از مانیتورینگ وصل به بیمار
2
شرح متغیر پیامد
فشار خون میانگین
مقاطع زمانی اندازهگیری
بلافاصله و همچنین در دقایق 1، 2، 3، 4 و 5 بعد از لوله گذاری و خارج کردن لوله اندازه گیری می شود.
نحوه اندازهگیری متغیر
با استفاده از مانیتورینگ وصل به بیمار
3
شرح متغیر پیامد
اضطراب
مقاطع زمانی اندازهگیری
قبل از القا بیهوشی اندازه گیری می شود.
نحوه اندازهگیری متغیر
معیار اندازه گیری بصری
4
شرح متغیر پیامد
راحتی
مقاطع زمانی اندازهگیری
قبل از القا بیهوشی اندازه گیری می شود.
نحوه اندازهگیری متغیر
معیار اندازه گیری بصری
5
شرح متغیر پیامد
درد
مقاطع زمانی اندازهگیری
قبل از خروج از بخش ریکاوری و در ساعات 1، 3و 6 بعد از جراحی
نحوه اندازهگیری متغیر
معیار اندازه گیری بصری
6
شرح متغیر پیامد
فشار خون سیستولیک و دیاستولیک
مقاطع زمانی اندازهگیری
هر 15 دقیقه در طول بیهوشی و همچنین قبل از خروج از بخش ریکاوری
نحوه اندازهگیری متغیر
با استفاده از مانیتورینگ وصل به بیمار
7
شرح متغیر پیامد
ضربان قلب
مقاطع زمانی اندازهگیری
هر 15 دقیقه در طول بیهوشی و همچنین قبل از خروج از بخش ریکاوری
نحوه اندازهگیری متغیر
با استفاده از مانیتورینگ وصل به بیمار
8
شرح متغیر پیامد
مقدار شاخص دوطیفی در طی بیهوشی عمومی
مقاطع زمانی اندازهگیری
قبل از القای بیهوشی عمومی، پس از القای بیهوشی عمومی، و در دقایق ۱۵، ۳۰، ۴۵، ۶۰ و بعد از اکستوباسیون
نحوه اندازهگیری متغیر
پایش مداوم با استفاده از دستگاه اندازهگیری شاخص دوطیفی و حسگر یکبارمصرف پیشانی
متغیر پیامد ثانویه
1
شرح متغیر پیامد
میزان مصرف داروی مخدر (مرفین) برای بی دردی در بخش ریکاوری
مقاطع زمانی اندازهگیری
در بخش ریکاوری اندازه گیری می شود.
نحوه اندازهگیری متغیر
بر حسب میلی گرم داروی تزریق شده توسط پرسنل بیهوشی
گروههای مداخله
1
شرح مداخله
گروه کنترل1: گروه کنترل: هدفون بیسیم سوراخدار روی هر دو گوش قرار داده میشود و بیماران هیچگونه محرک یا مداخله تحریک صوتی دریافت نمیکنند. هدفون سوراخدار امکان شنیدن صدای محیط را فراهم میکند
طبقه بندی
دارو نما
2
شرح مداخله
گروه کنترل 2: هدفون بیسیم غیرفعال روی هر دو گوش قرار داده میشود تا شدت صدای محیط به کمتر از 5 دسیبل برسد و بیماران در این گروه هیچ محرک صوتی دریافت نمیکنند.
طبقه بندی
دارو نما
3
شرح مداخله
گروه مداخله: بیماران تحریک صوتی با فرکانس 5 هرتز و شدت صوت 50 دسی بل بوسیله هدفون بی سیم را دریافت می کنند.
طبقه بندی
درمانی - وسایل
4
شرح مداخله
گروه مداخله: بیماران تحریک صوتی با فرکانس 10 هرتز و شدت صوت 50 دسی بل بوسیله هدفون بی سیم را دریافت می کنند.
طبقه بندی
درمانی - وسایل
5
شرح مداخله
گروه مداخله: بیماران تحریک صوتی با فرکانس 20 هرتز و شدت صوت 50 دسی بل بوسیله هدفون بی سیم را دریافت می کنند.
طبقه بندی
درمانی - وسایل
6
شرح مداخله
گروه مداخله: بیماران تحریک صوتی با فرکانس 50 هرتز و شدت صوت 50 دسی بل بوسیله هدفون بی سیم را دریافت می کنند.
طبقه بندی
درمانی - وسایل
7
شرح مداخله
گروه مداخله: بیماران تحریک صوتی با فرکانس 100 هرتز و شدت صوت 50 دسی بل بوسیله هدفون بی سیم را دریافت می کنند.
طبقه بندی
درمانی - وسایل
مراکز بیمار گیری
1
مرکز بیمار گیری
نام مرکز بیمار گیری
بیمارستان امام رضا
نام کامل فرد مسوول
سعید محمدی
آدرس خیابان
کرمانشاه، سرخلیجه، بلوار پرستار، بیمارستان امام رضا
شهر
كرمانشاه
استان
کرمانشاه
کد پستی
6742775333
تلفن
+98 83 3427 6300
ایمیل
dr.saidmohamadi@gmail.com
2
مرکز بیمار گیری
نام مرکز بیمار گیری
بیمارستان امام خمینی
نام کامل فرد مسوول
ُسعید محمدی
آدرس خیابان
کرمانشاه، خیابان نقلیه، بیمارستان امام خمینی
شهر
كرمانشاه
استان
کرمانشاه
کد پستی
6718743161
تلفن
+98 83 3728 3602
ایمیل
dr.saidmohamadi@gmail.com
حمایت کنندگان / منابع مالی
1
حمایت کننده مالی
نام سازمان / نهاد
دانشگاه علوم پزشکی کرمانشاه
نام کامل فرد مسوول
سیروس جلیلی
آدرس خیابان
کرمانشاه، بلوار شهید بهشتی، ساختمان شماره 2 علوم پزشکی، معاونت تحقیقات و فناوری
شهر
کرمانشاه
استان
کرمانشاه
کد پستی
6714673159
تلفن
+98 83 3838 6835
ایمیل
research_it@kums.ac.ir
ردیف بودجه
کد بودجه
آیا منبع مالی همان سازمان یا نهاد حمایت کننده مالی است؟